BJQCJ - FA-1030 NEUTRAL
- MSDS: BJQCJ
- Manufacturer: CLIFTON ADHESIVE INC
- Product Name: FA-1030 NEUTRAL
- National Stock Number: 8040-00-515-2246
Product Identification
Product ID:FA-1030 NEUTRAL
MSDS Date:09/14/1988
FSC:8040
NIIN:00-515-2246
Kit Part:Y
MSDS Number: BJQCJ
Responsible Party
WAYNE, NJ 07474-0832
US
Emergency Phone: 201-694-0845
Info Phone: 201-694-0845
Cage: 79833
Contractor
Telephone: 201-694-0845; 973-694-0845
Cage: 79833
Ingredients
TOLUENE (SARA III)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 34%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
RUBBER SOLVENT
CAS: 8030-30-6
RTECS: DE3030000
Fraction By Weight: 36%
ACGIH TLV: 400 PPM
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NAUSEA AND/OR NARCOSIS. MAY CAUSE
NERVE DAMAGE.
Effects of Overexposure:IRRITATION TO EYES AND MUCOUS MEMBRANES.
DRYNESS AND CRACKING OF SKIN. LIQUID INGESTION MAY CAUSE VOMITING.
NUMBNESS, TINGLING AND WEAKNESS OF ARMS OR LEGS.
Medical Cond Aggravated by Exposure:RESPIRATORY AILMENTS.
First Aid
First Aid:SKIN:WASH WITH SOAP AND WATER. REFER TO PHYSICIAN IF
IRRITATION PERSISTS. EYS:FLUSH EYES ABUNDANTLY WITH CLEAN WATER AND
REFER TO A PHYSICIAN. INGESTION:DO NOT INDUCE VOMITING. REFER TO A
PHYSICIAN. E XCESSIVE INHALATION:REMOVE PATIENT TO FRESH AIR OR
GIVE OXYGEN. USE CPR IF PATIENT IS NOT BREATHING. REFER TO
PHYSICIAN.
Fire Fighting
Flash Point Method:CC
Flash Point:< 0F/<- 18C
Lower Limits:0.9
Upper Limits:8.0
Extinguishing Media:CO2, FOAM, DRY CHEMICAL
Fire Fighting Procedures:NIOSH/MSHA APPROVED SCBA SHOULD BE WORN. USE
WATER SPRAY TO COOL FIRE-EXPOSED STRUCTURES AND DISPERSE
VAPOR-CLOUD IF FIRE IS NOT PRESENT.
Unusual Fire/Explosion Hazard:VAPOR IS HEAVIER THAN AIR AND MAY TRAVEL
CONSIDERABLE DISTANCE TO A SOURCE OF IGNITION AND FLASHBACK.
Accidental Release
Spill Release Procedures:ABSORB SPILL IN SAND, EARTH, VERMICULITE,
OIL-DRI OR SOL-SPEED-DRI. SHOVEL ABSORBED MATERIAL INTO STEEL
CONTAINER AND COVER.
Handling
Handling and Storage Precautions:KEEP CONTAINERS TIGHTLY CLOSED AND
STORE IN APPROVED SOLVENT STORAGE AREA. KEEP AWAY FROM OPEN FLAME,
HEAT, SPARKS, HOT SURFACES AND OXIDIZING AGENTS.
Exposure Controls
Respiratory Protection:USE NIOSH-APPROVED ATMOSPHERE SUPPLYING OR AIR
PURIFYING RESPIRATOR FOR ORGANIC VAPORS AS REQUIRED TO MAINTAIN
EXPOSURE LEVELS BELOW RECOMMENDED LIMITS.
Ventilation:LOCAL:REMOVE VAPORS DURING
PROCESSING.MECHANICAL:EXPLOSION-PROOF EQUIP.SPECIAL:REDUCE VAPOR
CONCENTRATIONS BELOW LIMITS.
Protective Gloves:PVA GLOVES.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:PROTECTIVE CLOTHING AS REQUIRED TO PREVENT
SKIN CONTACT.
Work Hygienic Practices:KEEP AREA CLEAN. CLEAN UP SPILLS IMMEDIATELY.
PRACTICE GOOD PERSONAL HYGIENE.
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:152F,67C
Vapor Pres:76 @ 20C
Vapor Density:3.0
Spec Gravity:0.864
Appearance and Odor:TRAN. AROMATIC RUBBERY ODOR
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:AVOID HEAT, OPEN FLAMES, SPARKS AND HOT
SURFACES.
Hazardous Decomposition Products:OXIDES OF CARBON, ZINC, MAGNESIUM,
SULFUR AND HYDROGEN CHLORIDE.
Disposal
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL CHEMICAL AND SOLVENT WASTE DISPOSAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.